| Home • Quiz • Tips • Tutorials • Functional • Cert Q's • Interview Q's • Jobs • Testimonials • Advertise • Contact Us | ||
Document Categories:
What's New?
Contribute?Sample SpecsWhat's Hot? |
ALV report listing all the infotypes that are customized in a SAP system with the structure nameBy Swarna S, Tata Consultancy Services *&---------------------------------------------------------------------* *& Report ZINFOTYPE * *& Author : Swarna.S * *&---------------------------------------------------------------------* *& * *& This program lists all the infotypes maintained in SAP system * *&---------------------------------------------------------------------* REPORT zinfotype . TYPE-POOLS : slis. *Structure declaration for Infotypes for customer
TYPES : BEGIN OF ty_table,
infty TYPE infty,
pnnnn TYPE pnnnn_d,
END OF ty_table.
*Structure for infotype text
TYPES : BEGIN OF ty_itext,
infty TYPE infty,
itext TYPE intxt,
sprsl TYPE sprsl,
END OF ty_itext.
*Structure for output display
TYPES : BEGIN OF ty_output,
infty TYPE infty,
itext TYPE intxt,
pnnnn TYPE pnnnn_d,
END OF ty_output.
*internal table and work area declarations
DATA : it_table TYPE STANDARD TABLE OF ty_table INITIAL SIZE 0,
it_output TYPE STANDARD TABLE OF ty_output INITIAL SIZE 0,
it_ittext TYPE STANDARD TABLE OF ty_itext INITIAL SIZE 0,
wa_table TYPE ty_table,
wa_output TYPE ty_output,
wa_ittext TYPE ty_itext.
*Data declarations for ALV DATA: c_ccont TYPE REF TO cl_gui_custom_container, "Custom container object
c_alvgd TYPE REF TO cl_gui_alv_grid, "ALV grid object
it_fcat TYPE lvc_t_fcat, "Field catalogue
it_layout TYPE lvc_s_layo. "Layout
INITIALIZATION. START-OF-SELECTION. *select the infotypes maintained
SELECT infty
pnnnn
FROM t582a
INTO TABLE it_table.
*Select the infotype texts IF it_table[] IS NOT INITIAL. SELECT itext
infty
sprsl
FROM t582s
INTO CORRESPONDING FIELDS OF TABLE it_ittext
FOR ALL ENTRIES IN it_table
WHERE infty = it_table-infty
AND sprsl = 'E'.
ENDIF. *Apppending the data to the internal table of ALV output LOOP AT it_table INTO wa_table. wa_output-infty = wa_table-infty.
wa_output-pnnnn = wa_table-pnnnn.
* For texts
READ TABLE it_ittext INTO wa_ittext WITH KEY infty = wa_table-infty.
wa_output-itext = wa_ittext-itext.
APPEND wa_output TO it_output.
CLEAR wa_output.
ENDLOOP. * Calling the ALV screen with custom container CALL SCREEN 0600. *On this statement double click it takes you to the screen painter SE51. *Enter the attributes *Create a Custom container and name it CC_CONT and OK code as OK_CODE. *Save check and Activate the screen painter. *Now a normal screen with number 600 is created which holds the ALV grid. * PBO of the actual screen , Here we can give a title and customized menus *&---------------------------------------------------------------------* *& Module STATUS_0600 OUTPUT *&---------------------------------------------------------------------* * text *----------------------------------------------------------------------* module STATUS_0600 output. * SET PF-STATUS 'xxxxxxxx'. * SET TITLEBAR 'xxx'. endmodule. " STATUS_0600 OUTPUT * calling the PBO module ALV_GRID. *&---------------------------------------------------------------------* *& Module ALV_GRID OUTPUT *&---------------------------------------------------------------------* * text *----------------------------------------------------------------------* MODULE alv_grid OUTPUT. CREATE OBJECT c_ccont
EXPORTING
container_name = 'CC_CONT'.
CREATE OBJECT c_alvgd
EXPORTING
i_parent = c_ccont.
* Set field for ALV PERFORM alv_build_fieldcat. * Set ALV attributes FOR LAYOUT PERFORM alv_report_layout. CHECK NOT c_alvgd IS INITIAL. * Call ALV GRID
CALL METHOD c_alvgd->set_table_for_first_display
EXPORTING
is_layout = it_layout
CHANGING
it_outtab = it_output
it_fieldcatalog = it_fcat
EXCEPTIONS
invalid_parameter_combination = 1
program_error = 2
too_many_lines = 3
OTHERS = 4.
IF sy-subrc <> 0.
MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
ENDIF.
ENDMODULE. " ALV_GRID OUTPUT *&---------------------------------------------------------------------* *& Form alv_build_fieldcat *&---------------------------------------------------------------------* * text *----------------------------------------------------------------------* * <--P_IT_FCAT text *----------------------------------------------------------------------* FORM alv_build_fieldcat. DATA lv_fldcat TYPE lvc_s_fcat. CLEAR lv_fldcat. lv_fldcat-row_pos = '1'. lv_fldcat-col_pos = '1'. lv_fldcat-fieldname = 'INFTY'. lv_fldcat-tabname = 'IT_OUTPUT'. lv_fldcat-outputlen = 8. lv_fldcat-scrtext_m = 'Infotype'. lv_fldcat-icon = 'X'. APPEND lv_fldcat TO it_fcat. CLEAR lv_fldcat. lv_fldcat-row_pos = '1'. lv_fldcat-col_pos = '2'. lv_fldcat-fieldname = 'PNNNN'. lv_fldcat-tabname = 'IT_OUTPUT'. lv_fldcat-outputlen = 15. lv_fldcat-scrtext_m = 'Structure'. lv_fldcat-icon = ''. APPEND lv_fldcat TO it_fcat. CLEAR lv_fldcat. lv_fldcat-row_pos = '1'. lv_fldcat-col_pos = '3'. lv_fldcat-fieldname = 'ITEXT'. lv_fldcat-tabname = 'IT_OUTPUT'. lv_fldcat-outputlen = 60. lv_fldcat-scrtext_m = 'Description'. lv_fldcat-icon = ''. APPEND lv_fldcat TO it_fcat. CLEAR lv_fldcat. ENDFORM. " alv_build_fieldcat *&---------------------------------------------------------------------* *& Form alv_report_layout *&---------------------------------------------------------------------* * text *----------------------------------------------------------------------* * <--P_IT_LAYOUT text *----------------------------------------------------------------------* FORM alv_report_layout. it_layout-cwidth_opt = 'X'. it_layout-zebra = 'X'. ENDFORM. " alv_report_layout * PAI module of the screen created. In case we use an interactive ALV or *for additional functionalities we can create OK codes *and based on the user command we can do the coding. *&---------------------------------------------------------------------* *& Module USER_COMMAND_0600 INPUT *&---------------------------------------------------------------------* * text *----------------------------------------------------------------------* module USER_COMMAND_0600 input. endmodule. " USER_COMMAND_0600 INPUT Create the
screen 0600 for the above program and place a custom container on the same:
Name the custom container as CC_CONT.
Also enter the attribute OK_CODE for the OK code as shown
above. Activate and execute the program:
|
|
|
Please send us your feedback/suggestions at webmaster@SAPTechnical.COM Home • Contribute • About Us • Privacy • Terms Of Use • Disclaimer • Safe • Companies: Advertise on SAPTechnical.COM | Post Job • Contact Us ©2006-2007 SAPTechnical.COM. All rights reserved. All
product names are trademarks of their respective companies. SAPTechnical.COM
is in no way affiliated with SAP AG. Graphic Design by Round the Bend Wizards |
||